Answers are grounded in this paper and cite their sources.
To address the forebay flow disorder and asymmetric unit inflow induced by a 90° sharp-bend approach channel, a multi-objective evaluation system was established combining physical modeling and numerical simulation. Parameter optimization of the porous curved guide wall was conducted via CFD, orthogonal experiments, and the Entropy-weight TOPSIS method. The results show that the optimized scheme effectively eliminated the large-scale recirculation zone induced by the 90° bend, reducing its volume by 62.32%. The axial velocity uniformity in the forebay was substantially improved, with a maximum increase of 103.46%. Furthermore, the velocity-weighted average flow deviation angle of the Unit 1 intake conduit decreased from 13.36° to 5.26°, achieving a reduction of 60.63%. This study confirms that rational parameter configuration of the porous curved guide wall can successfully regulate flow patterns in complex bend intake systems and enhance unit inflow quality. The optimized scheme yields remarkable effects, providing a reference for the design and management of similar engineering projects.
No takes yet. Share an insight, caveat, or question.
Li et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: