Three-dimensional reconstructions of Wendelstein 7-X (W7-X) equilibria incorporating soft X-ray measurements are presented. The STELLOPT code [2] has been enhanced to include soft X-ray measurements, complementing the set of diagnostics accessible for equilibrium search. The approach is based on the alignment of radiation strength with magnetic flux surfaces, which is justified for most W7-X plasmas. The emissivity reconstruction works reliably and reproduces measurements within the expected range of uncertainty. Results are in line with independent tomographic inversion methods for calculating radiation patterns, offering an alternative way of analyzing the soft X-ray signals. A comparison of the magnetic axis shift found in the equilibria as well as the tomograms shows overall agreement. The methods are demonstrated for three W7-X experimental programs, covering different magnetic field configurations and plasma parameters, including high performance plasma cases with volume averaged plasma beta of up to 2 %, central beta of up to 7 % and magnetic axis shift of up to 12 cm. For these experiments, the standard W7-X diagnostic set constrains the flux-surface geometry in the equilibrium reconstruction to an accuracy of about 6 mm.