This study experimentally explores the influence of adding sodium citrate (Na 3 Cit) to a sodium nitrate (NaNO 3 ) electrolyte in electrochemical machining (ECM) of AISI 304 stainless steel when using a palladium-coated tool electrode. The machining voltage, duty cycle, and electrolyte concentration were adjusted, while the machining rate (MR) and overcut (OC) were assessed. Raising the voltage from 6 to 11 V increased the MR from 0.20 to 0.42 µm/ s for NaNO 3 ; however, NaNO 3 + Na 3 Cit reached 0.52 µm/ s at 11 V, which is about 24% higher. Within the same range, OC dropped from 343 to 221 µm for NaNO 3 and from 302 to 204 µm for the mixed electrolyte. At a 90% duty cycle, the NaNO 3 + Na 3 Cit mixture achieved an MR of 0.35 µm/s, compared to 0.30 µm/s for NaNO 3 alone; meanwhile, OC dropped to 220 and 240 µm, respectively. At an electrolyte concentration of 0.41 mol/L, the MR was 0.46 µm/ s for the mixed electrolyte and 0.44 µm/ s for NaNO 3 , with corresponding OC values of 210 and 230 µm. SEM observations showed cleaner, nearly circular holes with less sludge and sharper edge definition when using NaNO 3 + Na 3 Cit. The results show that citrate-enhanced electrolyte boosts MR, dimensional accuracy, and electrochemical stability by enhancing complexation, optimizing current distribution, facilitating removal of reaction products, and better localizing anodic dissolution.
No takes yet. Share an insight, caveat, or question.
Ayyavoo et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: