Answers are grounded in this paper and cite their sources.
Electrical stimulation of the vagus nerve has emerged as a promising bioelectronic therapy for inflammatory and neurological disorders. However, an important step of translation is to assess efficacy of vagal nerve stimulation (VNS) in a range of mouse models of human disease. As such, this study evaluated the safety, functionality, and chronic performance of a cuff electrode array for implantation on the abdominal vagus nerve of awake, freely moving mice. A custom four-electrode platinum cuff was implanted on the abdominal vagus nerve of C57BL/6 mice for 28 days. Mice received no stimulation ( n = 4) or chronic VNS ( n = 9; 1.8 mA, 100 µs/phase, 10 Hz, 3 h/day, 5 days/week). All the electrodes from no VNS mice are referred to as passive electrodes (n = 16). In stimulated mice, the electrode pair used to deliver stimulation is referred to as stimulated electrodes (n = 18) and the electrode pair used for recording from the nerve is referred to as unstimulated electrodes (n = 18). Electrochemical and electrophysiological measurements were taken pre- and post- chronic implantation and stimulation, and during 4 weeks of in vivo testing. There were no changes in the in vitro electrochemical impedance spectroscopy (EIS) and CIL of electrodes. Charge storage capacity of stimulated electrodes increased post implantation, potentially indicating changes to the electrode effective surface area. However, there were no significant increases in vitro of CSC values across all electrodes. Longitudinal in vivo measurement of EIS showed a Main effect of Time across all electrodes, likely due to tissue encapsulation. There were no differences in vivo CIL between stimulated, unstimulated and passive electrodes. However, the CG of stimulated electrodes was significantly lower than passive electrodes. ECAP thresholds in chronically stimulated mice were significantly higher than unstimulated mice ( p = 0.001). However, 100% of recorded electric thresholds (n = 77 recordings from n = 13 mice) remained below Shannon electrical safety limit (Shannon safety parameter k = 1.75) and the water separation window (216 µC/cm 2 /phase). Stimulation was well tolerated in awake mice, and there were no differences ( p ≥ 0.05) in vagal fascicle area from nerves taken from normal, no VNS and chronic VNS mice. Together, data show the abdominal vagus nerve cuff electrode is a safe platform for chronic stimulation in mice and provides a valuable technology platform for investigating bioelectronic therapies in transgenic and disease-specific mouse models.
No takes yet. Share an insight, caveat, or question.
Kalenther et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: