Key result
Novel ECG triad detects neonatal atrial flutter with ~81% sensitivity.
Why the study?
Neonatal atrial flutter is a rare type of macroreentrant supraventricular tachycardia, and this report introduces and validates a novel diagnostic triad for its immediate electrocardiographic identification.
Does a novel electrocardiographic triad (SIS pattern, DIS pattern, and reversed W or V signs in the inter-QRS segment) accurately diagnose neonatal atrial flutter in neonates?
Case Report (n=17)
No
Does a novel electrocardiographic triad (SIS pattern, DIS pattern, and reversed W or V signs in the inter-QRS segment) accurately diagnose neonatal atrial flutter in neonates?
This study introduces a novel electrocardiographic triad using standard limb leads that demonstrated 81% sensitivity for the immediate diagnosis of neonatal atrial flutter before adenosine administration.
Answers are grounded in this paper and cite their sources.
May aid rapid ECG diagnosis of neonatal atrial flutter; leaves open prospective validation before clinical use.
Neonatal atrial flutter (NAF) is a rare type of macroreentrant supraventricular tachycardia. In this report, we describe a case of atrial flutter in an 8-day-old neonate with a total anomalous pulmonary venous connection. Additionally, we introduce a diagnostic triad for electrocardiographic identification of this condition. This triad comprises three components: the Similar Shapes of Inter-QRS segments (SIS) in leads II, III, and aVF, Different Shapes of Inter-QRS Segments (DIS) in lead I, and the occurrence of one or multiple stretched M or inverted V shapes in the inter-QRS (IQS) segment in leads II, III, and aVF. We assessed the effectiveness of this triad through a validation cohort, using previously reported cases of neonatal atrial flutter from the literature. The sensitivity rates for detecting SIS and DIS patterns and the singular or multiple reversed W or V signs were 100%, 81%, and 100%, respectively. Furthermore, all three components of the triad were found in 81% of neonates diagnosed with atrial flutter. The emergence of this triad can be attributed to the elimination of the isoelectric segment in electrocardiography, caused by the extended duration of flutter waves originating from macro reentry within the atrium and the rapid atrial rate characteristic of atrial flutter.
No takes yet. Share an insight, caveat, or question.
Elaheh Malakan Rad (2024) conducted a case report in Neonatal atrial flutter (NAF) (n=17). Novel electrocardiographic diagnostic triad (SIS pattern in leads II, III, aVF; DIS pattern in lead I; reversed W or V signs in IQS of leads II, III, aVF) was evaluated on Sensitivity for detecting all three components of the electrocardiographic diagnostic triad in neonatal atrial flutter. The novel electrocardiographic triad (SIS pattern, DIS pattern, and reversed W/V signs) detected neonatal atrial flutter with 81% sensitivity for all three components and 100% for SIS and W/V signs.
Synapse has enriched 10 related papers. Consider them for comparative context: