Key result
Pharmacy blood pressure measurement yields ~4 mmHg higher systolic readings than guideline-based home monitoring.
Why the study?
Because validated sphygmomanometers are costly and less accessible, patients prescribed self-monitoring of blood pressure often visit private pharmacies where the environment and measurement conditions may influence readings.
Cross-Sectional (n=174)
Open-label
Randomized sequence of home SMBP and pharmacy SMBP
Yes
Answers are grounded in this paper and cite their sources.
Caution warranted with pharmacy BP readings; leaves open standardization of out-of-office measurements.
Background: Effective blood pressure (BP) monitoring outside medical office requires that each patient havevalidated sphygmomanometer. Due to their relatively high expense, these sphygmomanometers remain littleor not accessible in our working context. When self-monitoring of blood pressure (SMBP) is prescribed in theoffice, most patients go to private pharmacies where BP measurements are influenced by environment andmeasurement conditions.Aim: To determine influence of environment and measurement conditions on BP during SMBP in healthysedentary people in order to describe reality of practice of this method in our working context.Method: Prospective experimental transversal study including 174 volunteers (47 women), aged 18 to 25years. Systolic BP (SBP), diastolic BP (DBP), and heart rate (HR) were measured by home SMBP according tointernational guidelines and by private “pharmacies SMBP”. Information on environment and conditions of BPmeasurement was collected on form by each subject. Means and standard deviations of SBP, DBP, and HR werecalculated and compared from the measurements obtained.Results : The mean age of study population was 21.1±2 years (Table 1). Only 9.7% of pharmacy measurementswere taken in quiet environment (Figure 1). In study population, SBP, DBP, and HR measured by homeSMBP were significantly (p=0.00) higher than those measured by “pharmacies SMBP” (Table 2). However, nosignificant difference (p>0.5) was found between measurements obtained by home SMBP and those obtained by“ pharmacies SMBP “ in quiet environment (Table 3). All of the equipment used in pharmacies were validatedelectronic sphygmomanometers (Figure 2).Conclusion: The environment significantly influenced measurements performed in pharmacies. Compared tohome SMBP, “private pharmacies SMBP” in our working context does not follow international guidelines and istherefore influenced by environment and measurement conditions.
No takes yet. Share an insight, caveat, or question.
Appolinaire et al. (2023) conducted a cross-sectional in Healthy sedentary subjects undergoing blood pressure self-measurement (n=174). Private pharmacy blood pressure self-measurement (pharmacies SMBP) vs. Home blood pressure self-measurement (home SMBP) according to international guidelines was evaluated on Mean systolic blood pressure (SBP, mmHg) (p=0.00). Private pharmacy blood pressure measurement yielded higher systolic and diastolic pressures than guideline-based home SMBP.
Synapse has enriched 10 related papers. Consider them for comparative context: