Key result
Combined carotid duplex and transcranial Doppler detects rare intracranial hemodynamic patterns in innominate artery stenosis.
Why the study?
Innominate artery stenosis is an uncommon cause of cerebrovascular insufficiency with complex and often underrecognized hemodynamic manifestations.
Does combined extracranial duplex ultrasonography and transcranial Doppler improve the detection of typical and atypical hemodynamic flow patterns in patients with innominate artery stenosis?
Case Report (n=2)
Does combined extracranial duplex ultrasonography and transcranial Doppler improve the detection of typical and atypical hemodynamic flow patterns in patients with innominate artery stenosis?
Integrating transcranial Doppler with extracranial duplex ultrasonography enhances the early recognition and hemodynamic interpretation of innominate artery stenosis by detecting rare intracranial flow abnormalities.
Answers are grounded in this paper and cite their sources.
May identify rare intracranial flow patterns in innominate stenosis; leaves open diagnostic utility beyond case reports.
Innominate artery stenosis is an uncommon but clinically significant cause of cerebrovascular insufficiency with complex and often underrecognized hemodynamic manifestations. We present two cases highlighting the diagnostic value of combined extracranial duplex ultrasonography and transcranial Doppler in detecting both typical and atypical flow patterns. Beyond established findings such as tardus-parvus waveforms, reduced carotid velocities, and vertebral steal phenomena, our cases demonstrate rare intracranial features including alternating middle cerebral artery flow and diffuse waveform dampening. These findings underscore the importance of integrating intracranial and extracranial assessments to improve early recognition, refine hemodynamic interpretation, and guide appropriate confirmatory imaging and management strategies.
No takes yet. Share an insight, caveat, or question.
Oikonomou et al. (2026) conducted a case report in Innominate artery stenosis (n=2). Combined extracranial duplex ultrasonography and transcranial Doppler was evaluated on Detection of typical and atypical flow patterns in innominate artery stenosis. Combined extracranial duplex and transcranial Doppler in 2 cases of innominate artery stenosis detected rare intracranial features including alternating MCA flow and diffuse waveform dampening.
Synapse has enriched 10 related papers. Consider them for comparative context: