Key result
Solitaire Platinum 4x40 mm linked to ~2.8-fold higher first-pass reperfusion vs. 4x20 mm in Solumbra.
Why the study?
The effect of the longer, radiopaque Solitaire Platinum 4x40 mm stent retriever compared with shorter Solitaire stent retrievers in Solumbra technique thrombectomy required evaluation.
Observational (n=70)
Open-label
Yes
Answers are grounded in this paper and cite their sources.
May favor 4×40 mm retrievers for first-pass reperfusion in Solumbra; hypothesis-generating and requires randomized confirmation.
OBJECTIVE: The Solitaire Platinum 4×40 mm stent retriever contains radiopaque markers with a long length. We evaluated the effect of Solitaire Platinum 4×40 mm stent retriever in Solumbra technique thrombectomy, and compared it with shorter Solitaire stent retrievers. METHODS: A total of 70 patients who underwent Solumbra technique thrombectomy with equal diameter (4 mm) and different length (40 vs. 20 mm) Solitaire stent retrievers were divided into two groups : the Solitaire Platinum 4×40 mm stent (4×40) group and the Solitaire FR 4×20 mm stent or Solitaire Platinum 4×20 mm stent (4×20) group. The clinical outcomes, Thrombolysis in Cerebral Infarction score, the first pass reperfusion status, and complications were evaluated and compared between the two groups. Multivariate analysis was performed to evaluate the predictive factors for reperfusion and complete reperfusion from the first pass. RESULTS: Higher first-pass reperfusion and complete reperfusion were achieved in the 4×40 group (68.0% and 48.0%) than in the 4×20 group (46.7% and 33.3%; p=0.004 and 0.007, respectively). In multivariate analysis, radiopaque device and longer stent retriever were correlated with first-pass reperfusion (p=0.014 and 0.008, respectively) and first-pass complete reperfusion (p=0.022 and 0.012, respectively). CONCLUSION: Our study demonstrated the usefulness of the Solitaire Platinum 4×40 mm stent retriever, which led to higher firstpass reperfusion and complete reperfusion rates than the Solitaire FR 4×20 mm stent or the Solitaire Platinum 4×20 mm stent, especially in Solumbra technique thrombectomy.
No takes yet. Share an insight, caveat, or question.
Yi et al. (2020) conducted an observational in Acute ischemic stroke caused by large artery occlusion (n=70). Solitaire Platinum 4x40 mm stent retriever vs. Solitaire FR 4x20 mm or Solitaire Platinum 4x20 mm stent retriever was evaluated on First-pass reperfusion (modified TICI 2b or 3 with the first pass) (OR 2.81, 95% CI 1.34-4.10, p=0.008). Solitaire Platinum 4x40 mm stent retriever increased first-pass reperfusion compared to 4x20 mm stents in Solumbra thrombectomy.
Synapse has enriched 10 related papers. Consider them for comparative context: