Key result
Sonographer-based pediatric echo labs achieve an ~8-point lower repeat examination rate than physician-only models.
Why the study?
The organization of pediatric echocardiography services varies widely across health care systems, with some laboratories integrating specialized sonographers and others relying solely on physicians. Evaluating the clinical, academic, and financial impact of both models is needed to help centers choose an structure suited to their demands and resources.
Answers are grounded in this paper and cite their sources.
May support sonographer-based models to enhance pediatric echo efficiency; leaves open generalizability beyond these centers.
Echocardiography has evolved the first-line imaging for diagnosis and management of pediatric and congenital heart disease all over the world. While it recognized as essential component of pediatric cardiac care delivery, organization of pediatric echocardiography services is very heterogeneous across the world, mainly related to significant differences in material and human resources in heterogeneous health care systems. In this paper, we focus on the role of pediatric sonographers, defined as expert technicians in pediatric echocardiography. While in some services sonographers are an essential part of the organizational structure, other laboratories operate only with physicians trained in echocardiography. The impact of sonographers on clinical, academic and financial performance will be discussed. Two organizational models (with and without sonographers) will be compared, and the advantages and disadvantages of each model will be evaluated. Different models of care provision are possible and decisions on organizational models need to be adjusted to the demands and available resources.
No takes yet. Share an insight, caveat, or question.
Arbic et al. (2022) conducted a review in Pediatric and congenital heart disease. Sonographer-based pediatric echocardiography laboratory model vs. Physician-based pediatric echocardiography model was evaluated on Annual transthoracic echocardiogram volume and repeat examination rate for inadequate image acquisition. Sonographer-based pediatric echocardiography laboratories achieved a lower repeat echo rate and higher annual volume (13,386 vs 8,500-9,000 TTEs) than physician-only models.
Synapse has enriched 10 related papers. Consider them for comparative context: