Key result
CT perfusion yields ~95% diagnostic accuracy vs. MR perfusion for target mismatch in stroke.
Why the study?
Rapid identification of the ischemic penumbra in acute cerebrovascular stroke is essential for timely therapeutic decision-making, prompting a comparison of the diagnostic performance and clinical outcomes of computed tomography perfusion versus magnetic resonance perfusion.
Does computed tomography perfusion provide comparable diagnostic performance and clinical outcomes to magnetic resonance perfusion in patients with acute ischemic stroke presenting within 24 hours of symptom onset?
Cohort (n=40)
Does computed tomography perfusion provide comparable diagnostic performance and clinical outcomes to magnetic resonance perfusion in patients with acute ischemic stroke presenting within 24 hours of symptom onset?
CT perfusion shows excellent agreement (95% diagnostic accuracy, Kappa=0.893) with MR perfusion for detecting perfusion-diffusion mismatch in acute ischemic stroke, supporting its use as a reliable imaging modality for early stroke assessment.
Answers are grounded in this paper and cite their sources.
Supports CTP as feasible alternative for mismatch detection in acute stroke; leaves open randomized validation of clinical impact.
Background: Rapid identification of ischemic penumbra in acute cerebrovascular stroke is essential for timely therapeutic decision-making. Perfusion imaging using computed tomography perfusion (CTP) and magnetic resonance perfusion (MRP) plays a major role in evaluating cerebral hemodynamics and detecting salvageable brain tissue. Aim: To compare the diagnostic performance and clinical outcomes of CTP versus MRP in cases with acute ischemic stroke. Methods: This prospective research included forty cases presenting within twenty-four hours of symptom onset and clinically suspected of acute cerebral infarction. Cases have been divided equally into two groups: CTP (num.=20) and MRP (num.=20). Clinical characteristics, perfusion parameters, mismatch detection, treatment interventions, and clinical outcomes (NIHSS and mRS) were analyzed. Diagnostic performance of CTP was evaluated using MRP as the reference standard. Results: Baseline clinical characteristics and treatment variables were comparable between groups. Core infarct volume was significantly greater in the CTP group (p equal to 0.041), while hypoperfused volume, mismatch volume, and clinical outcomes showed statistically insignificant variances (p above 0.05). CT perfusion demonstrated excellent agreement with MR perfusion in detecting target mismatch, with specificity of 87.5%, sensitivity of 100%, and overall diagnostic accuracy of 95% (Kappa=0.893). Conclusion: CT perfusion showed diagnostic performance comparable to MRI perfusion in detecting perfusion–diffusion mismatch in acute ischemic stroke and represents a reliable and widely available imaging modality for early stroke assessment.
No takes yet. Share an insight, caveat, or question.
Yassin et al. (2026) conducted a cohort in Acute cerebrovascular stroke / acute ischemic stroke (n=40). Computed tomography perfusion (CTP) vs. Magnetic resonance perfusion (MRP) was evaluated on Diagnostic performance in detecting target mismatch and clinical outcomes (NIHSS and mRS) (Kappa 0.893, p=>0.05). CT perfusion demonstrated 95% overall diagnostic accuracy compared with MR perfusion for detecting target mismatch in acute ischemic stroke.
Synapse has enriched 10 related papers. Consider them for comparative context: