Answers are grounded in this paper and cite their sources.
Wavefront shaping can focus light through strongly scattering tissue, but the number of input modes that must be measured limits its use in living animals. Most implementations treat all input modes as equivalent, as in isotropic diffusive media. In forward-scattering tissue, however, multiply scattered light retains part of its incident direction, so the transmission to a target depth decreases with the angle of incidence. We exploit this anisotropy by foveating the input basis: small angles are sampled finely and large angles are grouped into coarser modes, so that each mode carries a similar share of the transmitted light at a fixed total number of modes. With identical numbers of modes and measurements, foveation increased the peak-to-background ratio up to 2.5-fold through tissue phantoms and the two-photon signal from neurons in the living mouse brain 2.2-fold. Matching the input basis to the angular transmission of tissue thus improves wavefront shaping without additional mode measurements or hardware upgrades.
No takes yet. Share an insight, caveat, or question.
Jin et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: