Answers are grounded in this paper and cite their sources.
Cooling for semi-sealed greenhouses has emerged as a critical challenge, since restricted natural ventilation directly exposes crops to severe summer heat stress, threatening productivity and stability. This study extends the winter-focused Part I to summer operation by conducting a cooling-mode analysis of a hybrid trigeneration system, with the greenhouse heat-load model and major component models calibrated and validated against experimental data collected at the demonstration site, the cooling-load model reproducing the measured energy to within 2.22%. Two operational strategies were compared: an adaptive mode prioritizing waste-heat and solar-driven adsorption cooling, and a scheduled mode with predictive scheduling and chilled-water storage. The system met cooling loads of 25–75 kW on typical hot days and 94 kW on extreme hot days, while maintaining indoor air below 32 °C. Scheduled control reduced operational energy cost to 0.060–0.067 $/kWh, compared with 0.061–0.069 $/kWh for the adaptive mode. Under medium reference conditions, benchmark-based comparison showed positive primary energy savings of 5.9–19.9% and carbon saving ratios of 13.5–47.5% in cooling mode, although the magnitude of the benefit was sensitive to summer operating conditions. Local sensitivity analysis showed that a 10% reduction in fuel cell efficiency increased operational energy cost by 12.7%, while the same reduction in coefficient of performance of electrical heat pump increased them by 9.3%. These results correspond to the direct heat-utilization boundary; a complementary bounding analysis that accounts for the electricity of the temperature-upgrade step, together with a break-even criterion for the thermally driven cooling chain, is provided in the Discussion. This study provides one of the first techno-economic and benchmark-based assessments of greenhouse trigeneration cooling, demonstrating its potential to stabilize the summer greenhouse climate and support harvest extension, and clarifying, on a scenario basis, the year-round role of the proposed platform for controlled horticulture.
No takes yet. Share an insight, caveat, or question.
Bui et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: