Answers are grounded in this paper and cite their sources.
Wind turbine towers operating in wind-sand and saline-alkali environments are subjected to non-uniform coating erosion, which progressively exposes the local steel substrate and leads to cumulative corrosion during service. Because wind-sand-induced coating failure occurs non-uniformly, the steel substrate in different regions is exposed at different times, resulting in different corrosion ages and accumulated damage states. How to transfer the spatial distribution and temporal evolution of coating failure into a corrosion-damage model of the tower, and further quantify the effects of corrosion accumulation on structural dynamic response, fatigue life, and seismic fragility, remains a key issue in the life-cycle performance assessment of wind turbine towers exposed to wind-sand and saline-alkali environments. In this study, a 1.5 MW conical wind turbine tower is considered. Based on Bitter's erosion theory, rotor-wake characteristics, and regional wind-sand data, a coating damage assessment model is established, and a coating damage mass redistribution criterion is proposed to determine the location and time of first coating failure at the element level. The residual wall thickness and material properties of each element are then updated annually according to its corrosion age, thereby constructing an intact model and spatially non-uniform corrosion-accumulation models corresponding to 10 and 20 years of service. On this basis, the damage states at different service stages are introduced into a full-turbine finite-element model considering rotor-rotation effects, and wind-induced dynamic response, element-wise fatigue life, and seismic fragility are evaluated. The results show that the annual coating-failure probability in the non-wake region is 0.40%, higher than the 0.16% in the wake region, indicating a pronounced spatial difference in coating damage. The adverse effects of corrosion accumulation on structural performance become more pronounced under relatively high wind speeds and strong ground motions. Under the W7 wind condition, the minimum fatigue life of the 20-year corrosion-accumulation model is reduced by 50.44% compared with that of the intact model. When the peak ground acceleration (PGA) is 1.5g, the exceedance probability of the fourth limit state increases from 27.9% to 39.2%. These results indicate that spatially non-uniform damage aggravates the performance degradation of the tower. The proposed year-by-year corrosion-accumulation modeling method can characterize the structural performance evolution induced by regional differences in coating failure and corrosion age, providing a reference for the life-cycle performance assessment of wind turbine towers in wind-sand and saline-alkali environments.
No takes yet. Share an insight, caveat, or question.
Yu et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: