Answers are grounded in this paper and cite their sources.
To evaluate the mechanical properties of a denture base resin after repeated exposure to an alternative disinfection treatment using low-pressure non-thermal oxygen plasma (O₂ NTP). For each assay, the resin (ProBase ® Hot, Ivoclar) samples were prepared using the heat-compression mold technique. They were exposed to one or six low-pressure or O 2 NTP treatments for 120 min ( n = 10/group). Dimensional stability, surface hardness, flexural strength and elastic modulus were evaluated before and after low pressure and O 2 NTP treatments. SEM was used to observe the effect of the different treatments on the samples. Statistical analyses were performed using Student’s t-test or one-way ANOVA followed by a Tukey’s post hoc test according to the Shapiro-Wilk test normal distribution analysis ( p < 0.05). No adverse effects on the dimensional stability and surface hardness were noted after repeated O 2 NTP treatments. Flexural strength and elastic modulus were not significantly altered only if the resin was dehydrated under the controlled dry condition of this study. Indeed, SEM images revealed cracks on the samples surfaces only when moisture remained in the resin prior to plasma exposure. O 2 NTP could be a promising alternative approach to disinfect dentures, provided the resin’s hydration state is strictly controlled.