Evaluating conflicting early-stage design objectives, such as minimizing area-normalized cooling energy intensity (kWh/m2) and maximizing spatial Daylight Autonomy under static shading (sDA300/50%), is limited by the computational cost of building performance simulation. This study develops Random Forest surrogate models of Honeybee (EnergyPlus and Radiance) simulations for single-zone offices in the hot arid climate of Cairo, trained on 1037 parametric scenarios generated with a hybrid sampling strategy. In 10-fold cross-validation, the models reproduced the simulated cooling and heating intensities and four climate-based daylight metrics with an R2 of 0.943–0.990 and mean absolute percentage errors below 4% for all indicators except Annual Sunlight Exposure (7.9%), while reducing the evaluation time from about 55 s per simulation to about 0.3 s. Room depth and window-to-wall ratio were the most influential variables overall, and orientation dominated sunlight exposure. A surrogate-assisted multi-objective optimization, verified by 124 additional full simulations, showed that the surrogate overestimates daylight performance at the extremes of the design space; the verified Pareto front indicates that north- to north-east-facing rooms with the baseline glazing achieve an sDA above 90% at about 119 kWh/m2. The surrogate, deployed in an interactive tool, is best used for rapid screening, with final candidates confirmed by simulation.
No takes yet. Share an insight, caveat, or question.
Kareem S. Galal (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: