Background Full coverage of primary teeth with stainless steel crowns (SSC) has shown limited esthetic acceptance. Few studies have investigated hybrid polymer-based crowns (HPC) under critical loading in comparison with SSC and prefabricated zirconia crowns (ZRC) in vitro. Aim This in vitro study compared wear, wear of antagonist teeth, vertical marginal gap, fracture resistance, and color stability of HPCs with those of SSCs and ZRCs. Methods Fifteen 3D-printed identical dies were fabricated to receive prefabricated crowns, which were divided into 3 groups: (1) stainless steel (SSCs), (2) zirconia (ZRCs), and (3) hybrid polymer-based (HPCs). Vertical marginal gap was assessed by measuring the vertical distance between the crown and die margins before and after thermomechanical ageing to simulate 1 year. Crowns were optically scanned to analyse the average surface roughness. Wear assessment via Geomagic software was performed for crowns and antagonist teeth. Color change was evaluated via digital imaging method. Fracture resistance was assessed by applying a load until fracture, then failure mode was evaluated. Data were assessed with Kolmogorov–Smirnov and Shapiro–Wilk tests. Intergroup comparisons were performed using one-way ANOVA and Tukey’s post hoc test; intragroup comparisons used paired t-tests, and categorical data analysed with chi-square test. Results Statistically significant differences were found in the vertical marginal gap, where HPCs had the highest value, followed by ZRCs and SSCs ( P < 0.001); however, these values were all within clinically acceptable range. There was no statistically significant difference in surface roughness ( P > 0.016). SSCs presented the greatest amount of wear, followed by HPCs and ZRCs ( P < 0.001). Hybrid polymer-based crowns showed the greatest color change, followed by ZRCs ( P < 0.001). HPCs showed the greatest color change ( P < 0.001). SSCs had the highest fracture resistance (1713.00 ± 181.84 N), whereas HPCs (980.72 ± 132.41 N) and ZRCs (1039.63 ± 209.21 N) did not differ significantly. HPCs and SSCs exhibited surface deformation and microperforations, whereas ZRCs exhibited fracture. Conclusions HPCs, ZRCs, and SSCs had vertical marginal gap values within the clinically acceptable range, and no significant differences were found in surface roughness between groups. HPCs showed lower crown wear than SSCs and lower antagonist wear than ZRCs and SSCs. HPCs exhibited greater color change than ZRCs, while their fracture resistance was not significantly different from that of ZRCs.
No takes yet. Share an insight, caveat, or question.
Mohamed et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: