The Gringarten model provides an exact Laplace-domain solution for the timedependent produced-fluid temperature of a geothermal reservoir composed of multiple parallel vertical fractures in otherwise impermeable rock. This paper presents a timedomain series approximation, herein termed the G-series, derived through a linear expansion of a Laplace-domain exponential function. The explicit time-domain form reveals how the reservoir, fracture, and fluid parameters enter the solution and provides an analytically transparent alternative to numerical Laplace inversion. Using parameters from the Fervo Blue Mountain project, we evaluate a 5-term G-series against the exact Laplace solution. The results show that a practical difference of 0.5 C only occurs at long simulation times in the very strong thermal interaction regime, defined by a dimensionless Fourier number of Fo ≥ 1. Increasing the G-series truncation order from N = 5 to N = 10 produces no material improvement, indicating that the long-time error arises primarily from the first-order linearization rather than truncation of the summation. The G-series therefore provides a practical tool for early-stage geothermal well design and reservoir cooling forecasts within its demonstrated accuracy range.
No takes yet. Share an insight, caveat, or question.
Christopher L. Liner (2026) studied this question.