Answers are grounded in this paper and cite their sources.
Microbiologically influenced corrosion (MIC), particularly sulfur-induced MIC, arises from the colonization of microorganisms (e.g. bacteria or fungi) on the metal surface, initiating corrosion. Furthermore, sulfate-reducing bacteria (SRB) have been shown to produce corrosive byproducts, including hydrogen sulfide (H 2 S), which can compromise the protective oxide layer of stainless steel, thereby leading to pitting and structural damage to the metal surface. Even high alloyed CrNi-steels (e.g. 1.4571), particularly when ferritic lamellae or chemical inhomogeneities are present, could be damaged by this mechanism. The aim of the project was to identify the corrosion mechanisms in a commercially used austenitic stainless-steel pipe that exhibited two visible leakages and additional signs of pitting. A root cause analysis was conducted to investigate the microstructure, chemical composition of the pipe, and the role of MIC. The corroded areas were sectioned and metallographically prepared. Scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS) were used to characterize the biofilm composition. UV spectroscopy revealed lower levels of chromium and molybdenum than the normative values. This could reduce the steel material's overall corrosion resistance. The etched samples were examined using confocal laser scanning microscopy (CLSM), which revealed the characteristic austenitic microstructure with a high content of lamellar delta-ferrite grains. In these regions, there is a risk of localized material weakening due to accelerated corrosion. The results confirmed the presence of biofilm and sulfur on the internal surface of the pipe with ferritic lamellae preferentially affected by corrosion. The lack of chromium and molybdenum in combination with the identified microstructure, further weakened the passive layer, allowing H 2 S to accelerate pitting. This investigation demonstrates the influence of sulfur-induced MIC on stainless steel, leading to pitting-related failure. For industrial applications e.g. water-based piping systems, these findings highlight the importance of evaluating microbial and microstructural vulnerabilities for damage assessment and emphasize the need for preventive actions to extend the life expectancy of the pipes.
No takes yet. Share an insight, caveat, or question.
Huelsewede et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: