Answers are grounded in this paper and cite their sources.
Study Design: Retrospective cohort study. Objectives: To evaluate the safety of using larger lumbar pedicle screws than suggested by preoperative computed tomography (CT) and to assess the accuracy of CT imaging planes for screw selection. Summary of Background Data: CT is the gold standard for preoperative screw planning in lumbar spinal fusion. Although previous studies have examined the accuracy of screw placement, the ability of CT to predict the maximum pedicle screw size has not been well studied. In addition, there is a paucity of literature on pedicle expansion with screw placement. Methods: Patients undergoing primary 1- or 2-level minimally invasive transforaminal lumbar interbody fusion at L3-L5 by a single surgeon were included. Bilateral preoperative and postoperative pedicle width, height, and combined dimensions were measured on axial, sagittal, and coronal CT views. Bone density at each instrumented vertebra was assessed using Hounsfield Units (HU). Wilcoxon signed-rank tests compared preoperative and postoperative measurements and compared dimensions between imaging planes, and Spearman rank correlation evaluated associations between HU and pedicle expansion. Results: Twenty patients and 82 screws/pedicles were evaluated. Preoperative and postoperative pedicle widths differed significantly at L3-L5 on axial and coronal CT views (all P ≤0.012). Pedicle height differed at L4-L5 on sagittal CT (both P ≤0.004) and at L4 on coronal CT ( P <0.001). Overall, axial pedicle width increased by a mean of 1.68 mm (14.1%) and coronal short width by 1.50 mm (13.0%) following instrumentation. Width and height measurements differed significantly between axial versus coronal and sagittal versus coronal views preoperatively and postoperatively (all P <0.001). No correlation was identified between HU and the degree of pedicle expansion in any view (all P >0.100). Conclusions: Lumbar pedicles expand measurably after screw instrumentation, although this expansion appears independent of HU values. Reliance solely on axial or sagittal CT imaging may underestimate true pedicle size, whereas coronal reconstructions better reflect postinstrumentation dimensions and can improve screw selection. Integrating multiplanar CT data with correction factors may help maximize screw fixation. Level of Evidence: Level IV.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: