Answers are grounded in this paper and cite their sources.
Contrast sensitivity captures optical degradation that visual acuity may miss, but its clinical interpretation requires knowledge of test–retest variability and the influence of test conditions. We determined the visit-to-visit minimum detectable change (MDC₉₅) of the area under the log contrast sensitivity function (AULCSF) measured with the imo vifa and compared photopic (high-luminance surround) with mesopic (low-luminance surround) testing in 2,701 eyes of 1,968 patients undergoing cataract surgery at two centers. Visit-to-visit reproducibility was moderate (absolute-agreement intraclass correlation coefficient 0.575; 192 pairs), with an MDC₉₅ of 0.540 log units (0.356 after excluding large test–retest discrepancies). AULCSF improved more under photopic than mesopic testing (+ 0.545 vs + 0.269 log units; standardized response mean 1.36 vs 0.86), exceeding the MDC₉₅ in 50.5% vs 17.6% of eyes. Within the center performing both conditions, preoperative AULCSF was 0.34 log units lower under photopic testing, the postoperative difference narrowed to − 0.06, and improvement was larger by 0.28 log units (95% CI 0.24–0.32), robust to covariate adjustment. The photopic deficit increased with spatial frequency, consistent with veiling glare from lens scatter. Thus, the magnitude of cataract-related loss and postoperative gain registered by the test differed substantially by surround-luminance condition.
No takes yet. Share an insight, caveat, or question.
Yoneda et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: