Answers are grounded in this paper and cite their sources.
PURPOSE: To assess the accuracy, safety, and efficiency of respiratory-gated radiotherapy (RGRT) based on internal respiratory waveforms predicted by a hybrid long short-term memory (LSTM) deep-learning network, which adapts to breathing irregularities through the application of time-domain cross-correlation (TCC) to check and correct any residual phase/time shift in the LSTM predictions. METHODS: The adaptive LSTM-TCC model was built in two steps: (1) subject-specific LSTM models were trained to predict internal diaphragm motion from external bellows motion using each of 10 subjects' concurrent waveforms (≥20 Hz, 3-10 min) acquired from four-dimensional magnetic resonance imaging (4DMRI) protocol scans and (2) near real-time TCC was applied to the LSTM predictions to check and correct any residual phase/time shifts to safeguard against new breathing irregularities beyond the training data in the mid-term (3-10 min) and long-term (20-30 min) datasets. The testing datasets comprised both the mid-term and long-term concurrent motion waveforms, and the external-to-internal motion predictions and gating quality assessments for each subject were evaluated and validated with the actual internal motion as the ground truth. The hybrid LSTM-TCC models were compared with LSTM, TCC, and native external-to-internal correlation models. The temporal gating accuracy (beam-off and beam-on) and beam-gating quality (missing-target rate: %harm, and beam-on efficiency: %effic) of the hybrid LSTM-TCC model were evaluated and compared with LSTM, TCC, and native predictions. RESULTS: The hybrid LSTM-TCC models produced the highest long-term sustained correlations (C > 0.8, within 30 min), yielding the lowest %harm = 5 ± 6% and the highest %effic = 67 ± 15%, compared with the LSTM (%harm = 8 ± 8%, %effic = 65 ± 16%), the TCC (%harm = 29 ± 31%, %effic = 43 ± 19%), and the native (%harm = 37 ± 23%, %effic = 38 ± 14%). The hybrid LSTM-TCC models produced a high, sustained performance (C = 0.9 ± 0.1) without remodeling, regardless of new breathing irregularities, and the average temporal error of the predicted gating windows was ∆t < 0.3 s. CONCLUSION: This study assesses the simulated respiratory-gating qualities of four methods, demonstrating that the hybrid LSTM-TCC approach outperforms the native waveforms, the TCC method, and the LSTM models, yielding the highest correlation, gating accuracy, and %effic, but the least %harm. The hybrid LSTM-TCC model can safeguard LSTM predictions and gating accuracy against major breathing irregularities, demonstrating a strong potential for future clinical applications.
No takes yet. Share an insight, caveat, or question.
Milewski et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: