Answers are grounded in this paper and cite their sources.
A central-tube-free continuous helical-baffle heat exchanger with integral low-finned tubes (HBHE-LF) was compared experimentally with a conventional segmental-baffle exchanger (SBHE) using oil and water. Across four test series, the HBHE-LF showed 28.58%–36.70% higher overall heat-transfer coefficients based on the respective reference areas. At matched nominal oil flow rates, shell-side pressure drop and heat duty were 18.14% and 6.62% lower on average, respectively. Accounting for fin efficiency gave shell-side heat-transfer coefficients of 506–945 W/(m2·K). The performance evaluation criterion ranged from 2.72 to 2.90. Empirical correlations were developed for the shell-side Nusselt number and friction factor.
No takes yet. Share an insight, caveat, or question.
Huang et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: