In this study, the synthesis, characterisation and VOC sensing behavior of TiO₂–Hydroxyapatite (HaP) nanocomposites have been systematically explored. Using chemical co-precipitation technique, HaP was obtained in a simple and economical manner. To achieve enhanced crystallinity and stability, the sample was subjected to sintering at 800°C for 6 hours in a muffle furnace with a controlled heating rate of 5°C/min. Subsequently, the TiO₂ nanomaterial was integrated into the HaP matrix at incremental proportions (0.5, 1.0, 1.5, and 2.0 wt%) via the solid-state processing approach. Detailed evaluation of pure and composites samples covering structural, morphological, and chemical aspect were subjected to (XRD), X-ray diffraction, (FESEM), Field emission Scanning electron microscope, (EDX), Energy-dispersive X-ray spectroscopy, Raman spectroscopy, and (XPS) X-ray photoelectron spectroscopy. The incorporation of TiO 2 modified the phase and surface features of HaP composites. These composite samples were subjected to analyse for (VOCs) volatile organic compounds (ethanol, methanol, propanol, and acetone) sensing in ambient atmosphere. Notably, among all the composite samples, composite one wt% TiO 2 loaded had strongest performance against acetone vapors due to better surface reactivity and charge transport behaviour of TiO 2 and HaP. As the result 1.0 wt% TiO₂–HaP composite is a cost-effective, biocompatible material with strong potential for real-time acetone sensing.