Answers are grounded in this paper and cite their sources.
Ex vivo liver machine perfusion is increasingly used for graft assessment and reconditioning, but reproducible small-animal platforms remain limited. We developed a modular rat-mouse liver machine perfusion platform built around a shared extracorporeal circuit backbone with interchangeable cannulation interfaces, continuous inflow pressure monitoring, and a compact dry thermal-bead bath supporting benchtop subnormothermic and normothermic studies as well as cold-room hypothermic deployment. Performance was assessed by methylene blue perfusion mapping with pixel-based quantification and by blinded Suzuki histologic injury scoring. In mice, the portal cannulation site within the superior mesenteric vein-portal segment determined the completeness of whole-organ perfusion; positioning the cannula distal to the gastric/splenic/pancreatic tributary and proximal to the inferior pancreaticoduodenal vein ensured homogeneous lobar perfusion. In rats, single portal inflow left peripheral lobar regions relatively underperfused, whereas dual portal venous plus hepatic arterial inflow produced the most uniform perfusion (perfused surface area 58–75% vs. 100%). Histology showed preserved architecture on liver biopsies, with total Suzuki scores of 0–1 of 12 across procurement baseline, immediate perfusion, and cold storage plus reperfusion groups. Reproducible whole-organ perfusion demonstrated depends on species-specific vascular access. The current platform was validated for perfusion adequacy and short-term structural preservation; metabolically sustained support and functional viability remain to be demonstrated.
No takes yet. Share an insight, caveat, or question.
Cywińska et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: