Local chord and blade-twist perturbations can alter wind-turbine power and thrust, but their coupled responses require direct assessment. Using PHengLEI, unsteady Reynolds-averaged Navier–Stokes simulations examined the rigid rotor-only NREL 5 MW configuration at one below-rated operating point. Smooth step-weighted chord and blade-twist perturbations over Sections 8–16 formed a complete 3 × 3 matrix. All nine cases were advanced for six revolutions, with statistics evaluated over Revolutions 5–6. Baseline coefficient differences from reference values were below 3%. Case3 showed the largest tabulated thrust non-additivity (+14.22 percentage points). Case9 increased power by 15.05% and thrust by 18.53%, whereas Case8 increased power by 6.36% and thrust by 2.87%, providing a comparatively balanced response under the adopted percentage-based criterion. The earlier grid study showed a 1.89% Medium-to-Fine power difference, not a formal uncertainty bound. Physical time-step convergence remains unverified. These conditional results support complete-matrix assessment of coupled geometric effects and power–thrust trade-offs without establishing uncertainty-bounded design improvements.