Answers are grounded in this paper and cite their sources.
Patient-facing AI triage tools may support care-seeking and emergency department prioritization, but require evaluation beyond acuity accuracy alone. We developed SAFE-Triage, a framework integrating human review, automated metrics, LLM-as-judge evaluation, and simulation testing across clinical performance, patient interaction, and clinician-facing summary quality. We applied SAFE-Triage to 40 MIMIC-IV-derived emergency vignettes and a 10,030-case acuity analysis comparing prompted LLM triage (PLT) with rule-augmented prompted LLM triage (rPLT). PLT achieved higher emergency severity index (ESI) accuracy (57.5% vs 42.8%, $P < 0.001$), lower undertriage (13.1% vs 29.8%, $P < 0.001$), and higher clinician ratings across all domains. rPLT produced shorter and more stable outputs with higher automated readability scores. SAFE-Triage identified trade-offs between acuity accuracy, undertriage risk, communication quality, readability, and summary quality, supporting pre-deployment refinement and ongoing monitoring by showing where triage tools are efficient, need improvement, or need clinician oversight.
No takes yet. Share an insight, caveat, or question.
Heerschap et al. (2026) studied this question.