Answers are grounded in this paper and cite their sources.
Proton exchange membrane fuel cells (PEMFCs) are conventionally operated at 60–80 °C on kinetic and conductivity grounds. Increasing temperature can improve proton transport, while at fixed inlet relative humidity and total pressure it also increases the inlet water-vapour fraction and reduces reactant partial pressures. A validated three-dimensional two-phase model of a 20 cm 2 parallel-channel PEMFC at 150 kPa quantified this competition over 20–90 °C and 20–100% relative humidity (RH). Peak power density reached 0.997 W cm −2 at 40 °C, with 30–50 °C values within 1%, a broad plateau not a sharp optimum, falling 14.3% by 80 °C. Under saturation, heating from 40 to 80 °C raised proton conductivity 62% (6.34 to 10.30 S m −1 ) yet reduced current density 21% (2.16 to 1.71 A cm −2 ), as vapour rose from 4.9% to 31.6% of the gas. At a constant inlet dew point referenced to 40 °C and 50% RH, the peak power density still fell by 26.5% between 40 and 80 °C, showing that increasing inlet vapour dilution is not necessary for the thermal penalty. At 40 °C, peak power density varied by only 0.13% across 20–100% RH. PEMFC thermal setpoints reflect the coupled effects of proton transport, membrane hydration, reactant availability and water management, not temperature alone.
No takes yet. Share an insight, caveat, or question.
Badawy et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: