Answers are grounded in this paper and cite their sources.
The article examines the problem of the impact of prolonged wind exposure on the magnitude of heat loss through building envelope structures in the Far North. Based on an analytical review of regulatory documents, domestic and foreign scientific works, as well as archival data from the Anadyr weather station for the period from 2020 to 2025, an analysis of heat loss was carried out, taking into account the impact of wind exposure at the нормируемых values of outdoor air temperatures. Empirical relationships proposed by Frank and Jürges were used to determine the heat transfer coefficient for the outer surface of building envelope structures. The study showed that the standard value of the heat transfer coefficient, adopted in accordance with SP 50.13330.2024 “Thermal Protection of Buildings,” requires clarification for certain Arctic regions with high wind activity. Exceeding the standard value of the heat transfer coefficient αn is observed at wind speeds of 5–6 m/s for a rough surface and 7–8 m/s for a smooth surface. At speeds exceeding 15–20 m/s, the coefficient reaches a value of 37–70 W/(m²·°C), i.e., it exceeds the standard value by 1.6–3 times. Recommendations are proposed for adjusting thermal engineering calculations and improving the energy efficiency of buildings.
No takes yet. Share an insight, caveat, or question.
Kabantsev et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: