This work investigates reverse leakage current in Ni/Au Schottky diodes based on cubic GaN (c-GaN) and hexagonal GaN (h-GaN) using experimental characterization and technology computer-aided design (TCAD) simulations. Simulations were performed in Silvaco Victory Device using Shockley–Read–Hall recombination, Fermi–Dirac statistics, Schottky tunneling, and barrier-lowering effects to assess their ability to reproduce the measured reverse current–voltage (I–V) characteristics. The simulated results did not fully reproduce the experimental behavior, and variations in trap density and interface charge had a limited effect on the calculated leakage current within the investigated parameter ranges. The measured reverse current exhibited an approximately linear dependence on reverse voltage, which was not adequately described by the conventional transport models considered. An equivalent shunt resistance was therefore introduced to represent this non-ideal behavior, resulting in improved agreement between simulation and experiment. These findings highlight the limitations of the investigated transport models and the potential utility of an equivalent shunt resistance representation for modeling reverse leakage in c-GaN and h-GaN Schottky diodes.
No takes yet. Share an insight, caveat, or question.
Santis et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: