Key result
Using ≥7 guidewires is linked to ~3.2-fold higher CTO crossing failure versus 1–3 wires.
Why the study?
Guidewire escalation is central to CTO PCI, but the relationship between guidewire utilization burden and crossing failure after adjusting for lesion complexity and procedural characteristics was unclear.
Does higher guidewire utilization burden predict procedural crossing failure in chronic total occlusion percutaneous coronary intervention after adjustment for lesion complexity?
Observational (n=520)
No
Does higher guidewire utilization burden predict procedural crossing failure in chronic total occlusion percutaneous coronary intervention after adjustment for lesion complexity?
Answers are grounded in this paper and cite their sources.
In CTO PCI, high guidewire utilization burden correlates with higher crossing-failure rates, functioning primarily as a marker of underlying lesion complexity (such as higher J-CTO score) rather than a standalone independent predictor.
Background. Guidewire escalation is central to chronic total occlusion (CTO) percutaneous coronary intervention (PCI), but its relation to crossing failure is unclear. We assessed the association between guidewire utilization burden and crossing failure after adjustment for lesion complexity and procedural characteristics. Methods. We analyzed 520 consecutive CTO PCI procedures (2013–2023) from a single-center, single-operator registry. Crossing failure was defined as inability to cross the occlusion with a guidewire. Guidewire count was analyzed continuously and in predefined categories (1–3, 4–6, ≥ 7). Logistic regression was adjusted for J-CTO score, SYNTAX score, prior bypass surgery, target vessel, access site, and crossing approach. Results. Crossing failed in 40 procedures (7.7%). Failure rates were 4.9%, 8.8%, and 18.8% with 1–3, 4–6, and ≥ 7 guidewires (P for trend = 0.0002). Discrimination of guidewire count was modest (area under the curve [AUC] 0.646; 95% CI 0.557–0.736). After adjustment, continuous guidewire count was not significantly associated with failure (OR 1.13 per wire; 95% CI 0.98–1.30; P = 0.082), whereas ≥ 7 versus 1–3 guidewires remained associated (adjusted OR 3.22; 95% CI 1.23–8.45; P = 0.018). J-CTO score was the most consistent independent predictor (adjusted OR 2.19 per point; 95% CI 1.25–3.85; P = 0.006). Model AUC was 0.711 without and 0.733 with guidewire count (optimism-corrected 0.670). Conclusions. Higher guidewire burden was associated with higher crossing-failure rates but appears to function mainly as a marker of procedural difficulty rather than a stand-alone predictor. These exploratory findings, from a single-operator registry with few events and possible reverse causation, require confirmation.
No takes yet. Share an insight, caveat, or question.
Tayel et al. (2026) conducted an observational in Chronic total occlusion undergoing percutaneous coronary intervention (n=520). Guidewire utilization burden (>=7 guidewires) vs. Low guidewire utilization burden (1-3 guidewires) was evaluated on CTO crossing failure (inability to cross the occluded segment with a guidewire) (OR 3.22, 95% CI 1.23-8.45, p=0.018). Using >=7 guidewires was associated with higher CTO crossing failure vs 1-3 wires, though continuous wire count was not significant.