Key result
Hemi-Fontan with mBTTS takedown completely resolves severe mechanical hemolysis requiring ~32 interstage transfusions.
Why the study?
Clinically significant mechanical haemolysis generated by abnormal haemodynamics and pathologic shear forces in a modified Blalock-Thomas-Taussig shunt has been only rarely reported.
Case Report (n=1)
Answers are grounded in this paper and cite their sources.
Proximal innominate artery narrowing can exacerbate shear stress across a modified Blalock–Thomas–Taussig shunt, causing severe mechanical haemolysis and transfusion-responsive hypoxaemia that resolves upon shunt takedown.
Background: Mechanical haemolysis is a rare complication of modified Blalock–Thomas–Taussig shunt physiology. Abnormal shunt-related haemodynamics may generate pathologic shear forces resulting in clinically significant haemolysis, although this complication has been only rarely reported. Case presentation: A full-term infant with hypoplastic left heart syndrome underwent stage I Norwood palliation with placement of a 4.0-mm Gore-Tex modified Blalock–Thomas–Taussig shunt. The postoperative course was complicated by severe transfusion-dependent intravascular haemolysis, characterised by markedly elevated lactate dehydrogenase, plasma free haemoglobin, reticulocytosis, occasional schistocytes, and haemoglobinuria. A distinctive clinical feature was recurrent hypoxaemia that failed to improve with supplemental oxygen but consistently resolved following packed red blood cell transfusion. Extensive haematologic evaluation excluded alternative causes of haemolysis. Echocardiography demonstrated high-velocity flow across the shunt, while CT angiography revealed focal narrowing of the proximal innominate artery immediately proximal to the shunt origin, suggesting abnormal flow acceleration and increased shear stress. During the interstage period, the patient required 32 packed red blood cell transfusions. Following Hemi-Fontan completion with shunt takedown at 6 months of age, haemolysis resolved completely, and no further transfusions were required during hospitalisation or outpatient follow-up. Conclusions: Proximal innominate artery narrowing associated with a modified Blalock–Thomas–Taussig shunt may exacerbate shunt-related shear stress, resulting in clinically significant mechanical haemolysis and recurrent transfusion-responsive hypoxaemia despite preserved shunt patency. Mechanical haemolysis should be considered in infants with unexplained transfusion-dependent anaemia following systemic-to-pulmonary shunt placement.
No takes yet. Share an insight, caveat, or question.
Ali et al. (2026) conducted a case report in Hypoplastic left heart syndrome complicated by mechanical haemolysis post-modified Blalock-Thomas-Taussig shunt (n=1). Hemi-Fontan completion with modified Blalock-Thomas-Taussig shunt takedown was evaluated on Resolution of mechanical haemolysis and packed red blood cell transfusion requirement. Hemi-Fontan completion with mBTTS takedown at 6 months completely resolved severe mechanical haemolysis that had required 32 red blood cell transfusions during the interstage period.
Synapse has enriched 10 related papers. Consider them for comparative context: