Key result
ELCA successfully retrieves entrapped coronary guidewire after conventional methods fail, restoring TIMI 3 flow.
Case Report (n=1)
No
Excimer laser coronary angioplasty represents a safe, surgery-sparing bailout technique to retrieve an entrapped workhorse guidewire during PCI when conventional retrieval methods fail.
Answers are grounded in this paper and cite their sources.
May offer a nonsurgical bailout for entrapped guidewires; hypothesis-generating and requires prospective validation before adoption.
BACKGROUND: Guidewire entrapment is a rare (0.2%-0.8%) but serious complication of percutaneous coronary intervention (PCI), typically occurring in heavily calcified lesions, chronic total occlusions, or during bifurcation stenting. When conventional retrieval fails, surgical removal carries high morbidity. CASE SUMMARY: A 60-year-old man with 3-vessel coronary disease, prior inferior wall myocardial infarction, hypertension, and diabetes underwent staged PCI. A workhorse guidewire became entrapped in the distal left circumflex artery. Conventional retrieval attempts using multiple guidewires, microcatheters, and low-profile balloons failed. Excimer laser coronary angioplasty (ELCA) successfully freed the wire. Postprocedure angiography revealed TIMI flow grade 3 with localized dissection hematoma. DISCUSSION: To our knowledge, this is the first report of successful ELCA-assisted retrieval of an entrapped workhorse guidewire in a nonchronic total occlusion lesion after conventional techniques failed. ELCA offers a safe, surgery-sparing bailout option by ablating surrounding fibrocalcific tissue or polymer coating. TAKE-HOME MESSAGE: For entrapped guidewires refractory to conventional PCI retrieval, ELCA offers a safe, surgery-sparing alternative by ablating adjacent tissue or polymer coating, and early use prevents wire fracture, perforation, and emergent bypass grafting.
No takes yet. Share an insight, caveat, or question.
Ren et al. (2026) conducted a case report in Entrapped guidewire during percutaneous coronary intervention for 3-vessel coronary disease (n=1). Excimer laser coronary angioplasty (ELCA) vs. Failed conventional retrieval attempts (multiple guidewires, microcatheters, low-profile balloons) was evaluated on Successful retrieval of entrapped guidewire and postprocedure TIMI flow grade. Excimer laser coronary angioplasty successfully retrieved an entrapped guidewire in a 60-year-old man after conventional methods failed, achieving TIMI 3 flow without surgery.
Synapse has enriched 10 related papers. Consider them for comparative context: