A 1060 nm micro-electro-mechanical systems (MEMS) tunable vertical-cavity surface-emitting laser (VCSEL) is demonstrated with a movable distributed Bragg reflector (DBR). SiN x dielectric films of different residual stresses are prepared on a half-VCSEL with a Ge sacrificial layer by plasma-enhanced chemical vapor deposition. Suspended DBR mirrors supported by SiN x MEMS membranes are released by undercutting the Ge layer, and well-formed MEMS structures are achieved when the SiN x film is tensile-stressed. The frequency response of the bridge-type MEMS structure is characterized using a laser Doppler vibrometer, and it indicates that the resonant frequency and -3 dB bandwidth rise from 460 kHz and 646 kHz to 710 kHz and 890 kHz, respectively, as the tensile stress in SiN x is increased from 109 MPa to 302 MPa. Consequently, VCSELs with a SiN x membrane of optimized stress show a continuous single-longitudinal-mode tuning range of 97 nm. These findings demonstrate that residual stress in SiN x films has a significant effect not only on the structural stability but also on the frequency response of MEMS-VCSELs.
No takes yet. Share an insight, caveat, or question.
Lujiang et al. (2026) studied this question.