Answers are grounded in this paper and cite their sources.
Residual ambient dose equivalent rates are among the key quantities in operational radiation protection at nuclear and accelerator facilities. They are estimated prior to interventions to plan personnel dose exposure and optimize workforce allocation, and are routinely verified through radiation surveys during accesses. In this work, samples of three common materials used in accelerator sites - copper, steel, and titanium - were irradiated at the CHARM facility at CERN and their residual dose rates were measured under well-controlled conditions using a dedicated setup and two survey meters. The dose rate was monitored over nine measurement sessions, spanning from approximately eight hours to eight days after the end of irradiation, yielding a total of 177 data points used. An equivalent dataset was computed with the FLUKA Monte Carlo code and quantitatively compared to the measurements. Overall, 89% of the simulated values agreed with measurements within a factor of two. Agreement within 50% was achieved for the majority of titanium and steel samples. This work provides a significant residual dose rate dataset and demonstrates the capability of the FLUKA code to predict this quantity in complex, mixed-field, high-energy irradiation environments.
No takes yet. Share an insight, caveat, or question.
Lorenzon et al. (2026) studied this question.