Answers are grounded in this paper and cite their sources.
Hydrogen uptake and diffusion are critical factors governing hydrogen embrittlement susceptibility and are strongly influenced by surface conditions. This study investigates the effects of an electrochemically induced corrosion layers and passive films on hydrogen evolution reaction (HER) kinetics and hydrogen diffusion. Under cathodic polarization conditions, the passive film was unstable and provided marginal resistance to hydrogen diffusion. Transmission electron microscopy revealed that the electrochemically induced corrosion layer exhibited a bilayer structure, comprising an upper porous layer and a lower dense amorphous layer adhered to the matrix. To establish the relationship between the microscopic structure of the corrosion layer and hydrogen diffusion properties, the effects of the as-formed and delaminated corrosion layers on hydrogen diffusion were further examined. Compared with the pristine sample, the as-formed corrosion layer reduced effective diffusion coefficient (D eff ) and subsurface hydrogen concentration (C 0 ), whereas the delaminated corrosion layer increased both parameters. Kinetic analyses of HER and hydrogen adsorption-desorption processes indicated that the delaminated corrosion layer facilitated HER and subsequent hydrogen uptake, whereas the as-formed bilayer structure inhibited these processes under the experimental conditions investigated.
No takes yet. Share an insight, caveat, or question.
Chen et al. (2026) studied this question.