Answers are grounded in this paper and cite their sources.
Air leaks remain a common complication following pulmonary resections and can significantly impact postoperative outcomes. This experimental study aimed to evaluate the efficacy of WoundClot®, a topical hemostatic agent, in achieving aerostasis following non-anatomical lung resections in an ex vivo porcine lung model. Twenty fresh porcine pulmonary lobes were used. Each lobe underwent a standardized wedge resection using monopolar electrocautery. The airtightness of the defect was assessed using a submersion test. Subsequently, a 10 × 10 cm WoundClot® dressing was applied directly over the same defect, followed by reassessment. Burst pressure was measured by gradually increasing the inspiratory pressure until the first sign of air leakage (appearance of escaping air bubbles) occurred. Airtightness was scored using a standardized 4-point scale. Data were analyzed using the paired Student’s t-test and Wilcoxon signed-rank test. WoundClot® significantly improved both airtightness scores (p = 0.001) and burst pressure values (p = 0.013) compared to control. The dressing provided effective sealing of the resection site under simulated intraoperative pressures, with results comparable to previously reported sealants in similar models. WoundClot® demonstrated promising performance as a topical agent for sealing air leaks in a porcine lung model, supporting its potential applicability in pulmonary resections.
No takes yet. Share an insight, caveat, or question.
Delaca et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: