To estimate electromagnetic-field signal parameters within a short observation window, this paper presents a five-point method for signals with a known fundamental frequency. The signal model, comprising a DC component, a fundamental component, and a third harmonic, is expressed as a linear combination of sine and cosine basis functions. Five equally spaced samples form a 5 × 5 linear system, which is solved to obtain the DC component and the amplitudes and initial phases of the fundamental and third-harmonic components. The solution matrix can be calculated in advance from the sampling interval and known frequency to reduce real-time computation; the sampling interval must be selected so that the coefficient matrix is nonsingular and suitably conditioned. MATLAB/Simulink simulations were used to examine fundamental-only, third-harmonic, and time-varying-amplitude signals, while a parallel-plate power-frequency electric-field platform was used to evaluate steady-state and dynamic measurements. The results show that, when the signal follows the assumed model and the fundamental frequency is known, the method estimates the parameters from five samples. At a sampling interval of 1 ms, the first-to-last sample span is 4 ms, allowing changes in the electric-field amplitude to be observed. The method does not estimate frequency, and its practical accuracy depends on noise, sampling interval, matrix conditioning, and sensor errors.