Answers are grounded in this paper and cite their sources.
Hydrogen and helium targets are among the most frequently used targets in nuclear physics experiments. The placement of multi-wire proportional chambers (PC) and time projection chambers (TPC) inside such targets gives the detector many new possibilities, the practical implementation of which is an important and attractive, but very difficult task. This paper presents the final results of the studies on the performance of such gaseous hydrogen active targets as applied to the requirements of the MuCap experiment. A project to precisely measure the muon capture rate (reaction µ + р → ν + n) on a free proton with an accuracy of 1% was performed on the muon beam at PSI (Paul Scherrer Institute, Switzerland). The gas for the active target was ultra-pure deuterium-free hydrogen (protium) at a pressure of 10 atm. The rate of muon capture by a proton was calculated from the difference between the measurements of the lifetime μ– and comparing it with the lifetime of μ+ [1]. The arrival times, trajectories of incoming muons and outgoing decay electrons were measured using the TPC, which ensures the determination of the muon stopping point in the working volume of the detector and effective background suppression. By using the TPC as an active target and detecting the charged products of the muon capture reaction on impurities, it was also possible to monitor in real time the contamination of hydrogen with impurities with a sensitivity better than 1 × 10–8 volumetric units. Several special test setups [2, 3] were designed and manufactured at PNPI to study the operation of the PC and TPC under the proposed experimental conditions. Studies of PC aging were conducted under intense irradiation with radioactive alpha (241Am) and beta (90Sr) sources. It was demonstrated that PC can operate without degradation of properties at least up to an accumulated charge of 0.1 Coulomb/cm of anode wire length. Such radiation conditions are much higher than the irradiation conditions in a real experiment [1]. To drastically reduce impurities, all chambers were made of quartz glass with coated wire lamellas. The basic design idea of the detector was based on previous studies of the operation of drift chambers (DC) in gas mixtures of H2 + СН4 and Не + СН4, which are also presented in this work. TPC, PC and DC have been shown to be capable of operating in pure hydrogen at pressures up to 10 atm, providing gas gains up to 10 000.
No takes yet. Share an insight, caveat, or question.
Andreev et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: