Background C1 pedicle screw (CPS) fixation provides superior stability over C1 lateral mass screws (LMS) for atlantoaxial instability but is limited by anatomical variability and vascular risk. We propose a novel planning strategy that uses a patient-specific instrument (PSI) by 3D printing to improve the safety and accuracy of C1 CPS placement. Methods In this retrospective study, 22 patients underwent C1 CPS fixation using PSI between August 2015 and August 2025, with 44 screws implanted. Pedicles were classified according to the morphological classification proposed by Abhishek Srivastava et al. Screw trajectories were preoperatively planned, and PSIs were fabricated accordingly. Postoperative CT assessed screw placement accuracy using Gertzbein–Robbins (GR) grading. Results Twenty-two patients (9 males, 13 females; mean age 68.7 ± 13.1 years) were included. Morphological analysis of the C1 pedicles demonstrated a mean right-sided extramedullary height (EMH) of 3.81 ± 1.06 mm and intramedullary height (IMH) of 1.20 ± 1.05 mm, while the left-sided EMH and IMH were 3.92 ± 1.20 mm and 1.30 ± 1.11 mm, respectively. The 44 pedicles were classified as 16 Type 1A, 4 Type 1B, 1 Type 2, and 23 Type 3.