Landfills are important sources of particulate matter emissions (PM10 and PM2.5) generated by heavy machinery, vehicle traffic and particle resuspension. This study aimed to assess the dispersion of PM10 and PM2.5 at a Mexican sanitary landfill by coupling mathematical modeling with field monitoring. Using site-specific operational data and five years of meteorological data from the Toluca 76675 station (2021–2025), emission rates were estimated with the US EPA AP-42 emission factors for unpaved roads, aggregate handling and storage piles, and industrial wind erosion. Atmospheric dispersion was then simulated with the AERMOD modeling system on a grid of 100 × 100 receptors with 50 m spacing (4.95 km × 4.95 km). Field monitoring was conducted for one year at nine strategic points within the landfill with portable optical particle counters (Dust Particle Counter TC-8100), three days per week during the 12 h operating shift. In situ monitoring recorded the highest values at the excavation zone (PM10: 225.23 µg/m3; PM2.5: 173.08 µg/m3) and at the active working face (PM10: 212.43 µg/m3; PM2.5: 200.61 µg/m3), as annual averages of the operating shift; these concentrations exceed the WHO ambient air quality guideline values, although they are below the occupational exposure limits of NOM-010-STPS-2014. The model indicates that the plumes are oriented toward the SW and that the highest concentrations are located over the unpaved access road, the dominant source in the inventory.