An azimuth and elevation tracking turntable carrying a 1 m aperture primary mirror and a 700 kg class optical payload was designed for cryogenic absolute irradiance measurement. The static response and modes of the elevation support were calculated using an equivalent beam finite-element model. A dual-axis dynamic model incorporating eccentric gravitational torque, low-speed friction, transmission backlash, and three-component wind disturbances was developed to simulate multirate integrated control and the optical power response at the receiver plane. The design offset of the elevation assembly’s center of mass was reduced from 18.4 mm to 3.8 mm, lowering the corresponding maximum eccentric gravitational torque from 167.51 N·m to 34.59 N·m. The first-mode frequency of the equivalent beam increased from 25.21 Hz to 33.45 Hz. At mean wind speeds of 2.0, 9.6, and 10.0 m/s, the combined dual-axis root mean square (RMS) optical axis errors under full control were 1.505″, 1.533″, and 1.539″, respectively. At a mean wind speed of 2.0 m/s, the relative standard deviations of direct irradiance were 4.1047% under baseline control and 0.0738% under full control. At a nominal visibility of 60 km, the relative standard uncertainty of the retrieval was 4.39%.