Answers are grounded in this paper and cite their sources.
This study examined how the arrangement of longitudinal reinforcement influences visible alkali–silica reaction (ASR)-associated cracking at nearly constant longitudinal steel ratio. Fourteen concrete cylinders (200 mm × 400 mm) were exposed under nominal 38 °C or 60 °C conditions for approximately 65 d. Each exposure series contained an unreinforced reference and two independently cast cylinders for each of three reinforcement layouts: 3-D20 (S1), 6-D14 (S2), and 12-D10 (S3). Mapped crack trajectories were evaluated in terms of length density, global longitudinal–transverse balance B, and local directional dispersion HQ*. At 38 °C, lateral crack-length-density ranges decreased from S1 (10.35–10.59 m/m2) to S2 (4.60–6.15 m/m2) and S3 (3.09–4.17 m/m2); the 60 °C ranges overlapped. Both unreinforced references were transversely/circumferentially biased, whereas all twelve reinforced cylinders were longitudinally biased. The B group means decreased from S1 to S3 at 38 °C and increased from S1 to S3 at 60 °C, with overlap among the 38 °C individual B values. At 60 °C, HQ* was lower in S3 than in S2 and S1 across the independent-specimen ranges. An embedded–surface comparison within the common 14-day observation window used the valid records from each channel to examine layout-associated differences in the timing of central and surface longitudinal deformation. The results show that redistributing a nearly constant amount of longitudinal steel changes both the amount and directional organization of visible cracking.
No takes yet. Share an insight, caveat, or question.
Yang et al. (2026) studied this question.