Answers are grounded in this paper and cite their sources.
Asymmetric grid faults induce second-order harmonics in the DC-link voltage of three-phase AC/DC converters, leading to increased capacitor stress, reduced power quality, and compromised system stability. While sequence-decomposition-based control strategies effectively mitigate these effects, their practical adoption is often hindered by the computational overhead of synchronous reference frame transformations. Here, we propose and validate a Dual-Vector Current Control (DVCC) scheme operating primarily in the stationary reference frame for current regulation and reference generation, while employing minimal rotational transformations for sequence extraction. The control architecture employs a parallel arrangement of resonant filters to extract positive- and negative-sequence components, coupled with a notch-filter-based harmonic isolation stage to eliminate 100 Hz ripple without compromising transient response. Through analytical modeling and time-domain simulations under balanced and severely unbalanced grid conditions (voltage sag down to 0.85 p.u.), we demonstrate that under grid voltage sags down to 0.85 p.u., the proposed controller achieves a 92% reduction in DC-link voltage ripple compared to conventional PI control, and maintains input current total harmonic distortion below 7% under moderate unbalanced conditions (15% voltage sag) and below 3% under balanced conditions. Under severe single-phase loss (100% sag), THD increases to 37%, highlighting current limitations and the need for derating strategies. The bidirectional power transfer capability is preserved during fault transients, with settling times under 50 ms. These findings establish DVCC as a computationally efficient and robust alternative for grid-interfaced converters in distributed generation, electric vehicle charging, and microgrid applications, offering a practical pathway to enhanced grid resilience with minimal hardware modifications.
No takes yet. Share an insight, caveat, or question.
Tlili et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: