Answers are grounded in this paper and cite their sources.
This study investigated the influence of shielding gas purity on the microstructure and strain-rate-dependent tensile behavior of gas-tungsten-arc-welded commercially pure titanium Grade 2 joints. Two argon grades were compared: ultra-high-purity (UHP, 99.999%) and high-purity (HP, 99.997%). UHP shielding achieved full penetration at ~9.5% lower heat input, producing a narrower welded region. Welding transformed the fine, weakly textured base metal into coarser, moderately textured heat-affected zones and strongly textured lamellar/acicular fusion zones. HP shielding produced higher fusion-zone hardness, potentially associated with interstitial strengthening. All tensile specimens fractured within the heat-affected zone, while UHP shielding resulted in higher strength, elongation, and strain-rate sensitivity. Welding altered both the magnitude and strain evolution of strain-rate sensitivity, consistent with the combined influence of grain structure, crystallographic texture, and deformation mechanisms involving slip and twinning.
No takes yet. Share an insight, caveat, or question.
Salazar-Zapata et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: