Answers are grounded in this paper and cite their sources.
This study investigates the effects of fiber type and cover thickness of ultra-high-performance concrete (UHPC) on rebar corrosion protection in accelerated corrosion testing. Three UHPCs with steel-fiber-reinforced (UF0.5, 0.5 vol%), glass-fiber-reinforced (UG0.5, 0.5 vol%), and stainless-steel wire mesh (UWMT2.5) were applied as 25 mm UHPC covers over reinforced concrete (RC) samples under accelerated corrosion testing in 3.5 wt% NaCl solution for 150 days. UF0.5 covers at two thicknesses (20 mm, T2.0; 25 mm, T2.5) were additionally evaluated. Performance was assessed using the rebar mass loss ratio (Mloss), six-position chloride-ion profiles spanning both the UHPC cover and the underlying substrate, the connected porosity ratio, scanning electron microscopy, and mechanical properties. UHPC covering RC substantially outperformed the RC reference (Mloss = 100 %). UHPC with wire mesh (UWMT2.5) clearly reduced Mloss (80.61 %). Glass-fiber UHPC (UG0.5T2.5, Mloss = 33.91 %) further improved protection, while steel-fiber UHPC delivered the best corrosion protection: Mloss = 23.18 % (T2.5) and 23.80 % (T2.0). The Cl- content of the steel-fiber UHPC cover was lower than that of the RC substrate and other UHPC covers. A 20 mm steel-fiber UHPC cover may be a potential cover thickness to enhance corrosion protection of RC.
No takes yet. Share an insight, caveat, or question.
NGO et al. (2026) studied this question.