This study examines the repeated-impact responses of three ground-supported high-strength concrete (HSC) slabs reinforced separately with steel, glass fibre-reinforced polymer (GFRP) and basalt fibre-reinforced polymer (BFRP) bars. One 2.0 m × 2.0 m × 0.15 m slab per reinforcement type was subjected to successive nominal 600 kg impacts from 1, 5 and 13 m. Reinforcement strains were measured with 16 gauges per slab. Acceleration-derived mean responses were obtained by double integration of a processed mean acceleration history combining four triaxial accelerometers. At the 13 m event, the mean response peaks were 1.147, 1.888 and 2.448 mm for steel, GFRP and BFRP, respectively. Maximum bottom-mesh mean strain peaks across the sequences were 82.7, 262.3 and 5780.0 με, respectively. Final photographs show localized concrete fragmentation and exposed reinforcement in the steel and GFRP specimens and multiple contact marks with edge cracking in the BFRP specimen. The results characterize specimen response under accumulated loading. The single-specimen design, unmeasured ground stiffness, variable BFRP contact position and incomplete processing records limit generalization to reinforcement material performance.