Answers are grounded in this paper and cite their sources.
Background Accurate and reproducible patient positioning is essential for image-guided radiotherapy (IGRT) in cervical cancer. This study compared pretreatment setup reproducibility and treatment-course changes among three positioning–immobilization strategies using daily cone-beam computed tomography (CBCT) and repeated-measures analysis. Methods This retrospective study included 255 patients undergoing volumetric modulated arc therapy (VMAT) for cervical cancer: Group A, supine positioning with vacuum-cushion immobilization (n = 100); Group B, prone positioning with an Orfit body frame and thermoplastic fixation (n = 100); and Group C, prone positioning with an individualized belly-board system (n = 55). A total of 6,255 daily pretreatment CBCT registrations were analyzed. Pre-correction translational setup deviations in the longitudinal (LNG), lateral (LAT), and vertical (VRT) directions and the corresponding three-dimensional (3D) vector magnitude were evaluated. Generalized estimating equation (GEE) models accounted for within-patient correlation, with multivariable adjustment for age, body mass index, and irradiation field extent. Patient-level sensitivity analyses, descriptive setup-related uncertainty estimates, and threshold-based reproducibility analyses requiring simultaneous attainment in all three translational directions were also performed. Results In adjusted GEE analysis, 3D vector magnitude was greater in Group B (β = 0.0647 cm; 95% CI, 0.0077–0.1217; P = 0.026) and Group C (β = 0.1038 cm; 95% CI, 0.0342–0.1734; P = 0.003) than in Group A. Treatment fraction number was positively associated with 3D vector magnitude (β = 0.0032 cm/fraction; P < 0.001), without significant group-by-fraction interactions. Patient-level sensitivity analyses supported the overall between-group pattern. Direction-specific analyses showed greater longitudinal deviations in Group B and greater vertical deviations in Group C. Under the strict patient-level criterion requiring all three absolute directional deviations to remain ≤ 0.5 cm at every available CBCT verification, attainment rates were 43.0%, 28.0%, and 12.7% in Groups A, B, and C, respectively (P < 0.001). Conclusions The three positioning–immobilization strategies exhibited distinct patterns of pre-correction setup deviations during daily CBCT-guided VMAT for cervical cancer. Supine positioning with vacuum-cushion immobilization was associated with smaller 3D setup deviations and higher descriptive threshold-attainment rates than the two prone strategies in this cohort. These findings reflect pretreatment setup reproducibility rather than isolated immobilization-device performance, post-correction treatment accuracy, or recommended clinical planning margins. Clinical trial registration Not applicable. This study was a retrospective observational analysis of routinely collected clinical data. No prospective assignment of participants to study-related interventions was performed.
No takes yet. Share an insight, caveat, or question.
lin et al. (2026) studied this question.
Synapse has enriched 8 closely related papers on similar clinical questions. Consider them for comparative context: