Answers are grounded in this paper and cite their sources.
An Au-containing poly(lactic acid)–lipoic acid sorbent (AuPLA–Lip) was evaluated for orbital shaker-assisted dispersive micro-solid-phase extraction (OSA-DµSPE) coupled with gas chromatography–tandem mass spectrometry (GC–MS/MS). The target panel comprised six organophosphorus pesticides, three organochlorine pesticides and tetraconazole. The synthesized material was characterized using FTIR, 1 H NMR, DSC, SEM–EDS, XPS, TEM and TGA–DTG. A 2 4 factorial design with five centre points screened pH, sorbent dose, extraction time and working volume. The highest observed mean response was 84.98 ± 0.62% (SD between five run means) at pH 5, 62.5 mg sorbent, 10 min and 30 mL working volume. The reported linear range was 0.14–50 ng g −1 , with R 2 values of 0.989–0.999. LODs and LOQs estimated at signal-to-noise ratios of 3 and 10 were 0.017–0.045 and 0.053–0.137 ng g −1 , respectively. Fortification recovery mean values were 88.6–103.0% at the examined levels (n = 3 per level), and recovery mean value remained 91.0% after five reuse cycles. Application was examined in ten market vegetable extracts. These results data support AuPLA–Lip as a reusable extraction platform for the selected panel; sample-based reporting limits and quantitative residue conclusions require complete whole-method validation.
No takes yet. Share an insight, caveat, or question.
Sahito et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: