Answers are grounded in this paper and cite their sources.
Graphene-reinforced polymethyl methacrylate (G-PMMA) requires effective adhesion protocols for dental restorations. This study evaluated the effects of Al2O3 airborne-particles abrasion and an experimental primer on G-PMMA bonding to bovine enamel and dentin. Two hundred seventy-six bovine incisors were randomly allocated to 12 groups (n = 23) according to substrate (enamel/dentin), abrasion (none, 50 µm or 1B10 µm particles), and primer application (with/without). Shear bond strength (SBS), elastic modulus, maximum deformation and failure modes were evaluated. Interfacial morphology was examined using field-emission scanning electron microscopy (FESEM) and fluorescence microscopy. Mechanical outcomes were analyzed using a two-way analysis of variance (ANOVA). In enamel, abrasion and primer application significantly increased SBS (p < 0.001), with the highest values following 110 µm abrasion. In dentin, only primer application significantly increased SBS (p = 0.002). Significant interactions were observed between abrasion and primer, affected elastic modulus and maximum deformation in enamel, and elastic modulus in dentin. Surface treatments shifted failure patterns toward the interface between the luting material and the dental substrate. Microscopic analysis revealed micromechanical interlocking and the localization of the primer. Surface conditioning improved G-PMMA adhesion in a substrate-dependent manner. Abrasion was particularly effective in enamel, whereas primer application had a greater influence on dentin.
No takes yet. Share an insight, caveat, or question.
Ruiz et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: