Answers are grounded in this paper and cite their sources.
The Nottingham histological grading system (NHGS) for canine invasive mammary carcinoma relies on visual assessment, and inter-observer agreement remains below the accepted threshold for reliability, being lowest for nuclear pleomorphism (NP). We developed a deep learning system that scores all three NHGS components (tubule formation, TF; mitotic count, MC; and NP) on whole-slide images (WSIs) of confirmed canine invasive mammary carcinoma, with each score derived from a quantitative measurement rather than subjective assessment. A transformer-based segmentation network first delineates the mammary hyperplasia region on each WSI and produces a binary mask, which serves as a common spatial constraint for all three scoring modules. For TF, the glandular ratio (GR), defined as the proportion of tubule-structure pixels within the masked region, is computed at pixel level and replaces the pathologist's visual estimate of tubule proportion. For MC, mitotic figures are detected on image patches cropped from the masked region, and a greedy algorithm then selects the 10 densest non-overlapping high-power fields, thereby avoiding subjective selection of the counting area. For NP, a binary classifier detects patches containing nuclei fulfilling the score-3 morphological criteria, and the slide-level NP score is assigned from the proportion of positive patches, with the decision threshold calibrated on the validation set. The system was evaluated on 29 independent canine WSIs against the consensus of two senior veterinary pathologists. Seven feline mammary carcinoma WSIs, none of which were used in training and validation, were included as a preliminary cross-species exploration. Overall grading accuracy was 93.1% and the Gwet's AC1 was 0.919. Per-component agreement was 82.8% (TF), 86.2% (MC), and 72.4% (NP); given the markedly skewed score distributions, Gwet's AC1 was also calculated (0.771, 0.838, and 0.649). On the feline slides, overall accuracy reached 85.7%, with a bias pattern consistent with that observed in canine slides. This study was a feasibility investigation. The system generated NHGS grades without manual intervention, and the feline tissue results suggest that this method may be transferable to other companion animal species.
No takes yet. Share an insight, caveat, or question.
Guo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: